F220x / F224xFOM II SeriesDual Channel IsolatorTechnical Manual
Rev B Copyright Feb 2004
VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 PROPRIETARY DATA All data in this manual is proprietary and may not be disclosed, used or duplicated, for procurement or manufacturing purposes, without prior written permission by VERSITRON, Inc. WARRANTY
All VERSITRON products purchased after January 2001 carry a limited lifetime warranty against defects in material and workmanship. Purchases made prior to January 2001 are warranted for a period of one year from date of delivery. VERSITRON reserves the right to repair or, at our option, replace parts which during normal usage prove to be defective during the warranty period provide that: 1. You call VERSITRON at 302-894-0699 or 800-537-2296 and obtain a Return Maintenance Authorization (RMA) Number. Please reference your RMA number on the outside of the box the item is shipped in. 2. Shipping charges are pre-paid. No other warranty is expressed or implied and we are not liable for consequential damages. For repairs outside of the warranty period, the same procedure must be followed. TABLE OF CONTENTS
SECTION 1: DESCRIPTION OF EQUIPMENT1.1 INTRODUCTION 1.2 DESCRIPTION OF EQUIPMENT 1.2.1 Functional Characteristics 1.2.2 Physical Characteristics 1.3 SPECIFICATIONS SECTION 2: INSTALLATION2.1 GENERAL 2.2 SITE SELECTION AND MOUNTING 2.2.1 Signal Interface 2.2.2 User Selected Options 2.3 POWER REQUIREMENTS 2.4 INITIAL CHECKOUT PROCEDURE SECTION 3: OPERATION3.1 INTRODUCTION 3.2 STATUS INDICATORS/AUDIBLE ALARM 3.3 Operating Controls SECTION 4: THEORY OF OPERATION4.1 INTRODUCTION 4.2 DUAL CHANNEL TRANSMITTER F220x 4.3 DUAL CHANNEL RECEIVER F224x 4.4 POWER SUPPLY AND ALARM CIRCUITRY SECTION 5: MAINTENANCE AND TROUBLESHOOTING5.1 INTRODUCTION 5.2 FAULT ISOLATION List of ILLUSTRATIONS
1 . OVERALL VIEW, MODEL F220x ISOLATOR
List of TABLES
1. ENCLOSURES / CHASSIS 2. JUMPER LOCATIONS, MODEL F220x TRANSMITTER 3. JUMPER LOCATIONS, MODEL F224x RECEIVER 4 DB25F PIN ALLOCATIONS, MODEL F220x TRANSMITTER 5 DB25F PIN ALLOCATIONS, MODEL F224x RECEIVER 6. NON-OPERATIONAL INDICATORS SECTION 1DESCRIPTION OF EQUIPMENT1.1 INTRODUCTIONThis manual provides general and detailed information on the installation and operation of the Model F220x / F224x FOM II Series Dual Channel Isolators. Section 1 contains a general description of the equipment. Section 2 contains installation instructions. Section 3 contains operating instructions. Section 4 provides the theory of operation. Section 5 contains maintenance and troubleshooting information. Figure 1 is an overall view of the modem.
* Note: Multimode tests performed @ 100Kbps on 62.5/125µm fiber optic cable.Single mode tests performed @ 100Kbps on 10/125µm fiber optic cable.1.2 DESCRIPTION OF EQUIPMENTFunctional CharacteristicsModel F220x / F224x Isolators are fiber optic transmitters and receivers designed to allow for simplex information channels over a pair of fiber optic cables. Using both channels the unit may be configured as one data or clock channel plus one contact closure channel may be isolated and extended transparently. Model F220x / F224x Isolators use fiber optic cable up to 2km (1.25mi/6,560ft) for 850nm multimode optics, up to 6km (3.75mi/19,800ft) for 1300nm multimode optics, or up to 15km (9.375mi/49,500ft) for 1300nm single mode optics. The link is fully transparent and data agile from 250bps to 10Mbps (Balanced), 250bps – 100Kbps (Unbalanced). Model F220x / F224x Isolators fully support the interface control signals associated with the EIA RS-232, RS-449, RS-530, MIL-STD-188-114 Balanced/Unbalanced, TTL and NRZ standards. 1.2.2 Physical CharacteristicsModel F220x / F224x Isolators measure 7.0W x 0.84H x 11.6L in. (17.8 x 2.1 x 28.9 cm) and are designed for mounting in a variety of VERSITRON enclosures and chassis (see Table 1). Standalone options include enclosure Models HF-1 (single card) and HF-2 (dual card). Rack mount options for standard 19" racks include chassis Models HF-2SS (2-slot) and HF-20 (20-slot). Each Isolator installed in a HF-1, HF-2 or HF-2SS requires a power adapter Model PSAC08 (US) or PSAC09 (European) providing 12VDC, 1A with a one-pin connector for electrical input on the back of the card. There is a female DB25 connector for the digital interface and two ST connectors for the fiber optic interface, also on the back of the card. Isolators installed in a HF-20 require a Model AC150W Power Supply / System Monitor. Note that a Model AC150W utilizes two slots of the Model HF-20 chassis. Also, two power supplies are recommended for redundancy. Model F220x Transmitters have four LED indicators on the front panel: DC power on (PWR), loss of signal (ALM), transmit Ch. 1 data present (TXC1), and transmit Ch. 2 data present (TXC2). Model F224x Receivers have four LED indicators on the front panel: DC power on (PWR), loss of signal (ALM), receive data present (RX), and contact closure active (RSYNC). No audible alarm is available.
*¹ Note: US Model - PSAC08; European Model - PSAC09*² Note: One Power Adapter per Isolator required.TABLE 1. ENCLOSURES / CHASSIS
FIGURE 1. OVERALL VIEW, MODEL F220x ISOLATOR1.3 SPECIFICATIONSData Rate: Any data rate from 250bps - 10Mbps (Balanced), from 250bps - 100Kbps (Unbalanced). Operation: Dual channel simplex over a fiber optic cable pair.
Optical Interface: ST connectors. Digital Interface: Signal levels and format conform to EIA RS-232, RS-449, RS-530, MIL-STD-188-114 Balanced/Unbalanced, TTL and NRZ standards.
Electrical Interface: DB25 Female. Bit Error Rate: Better than 10-9. Dimensions: 7.0W x 0.9H x 12.2D in. (17.8 x 2.3 x 31.0 cm). Weight: 12.0 oz (0.34 kg). Power Requirements: HF-1, HF-2, or HF-2SS Installation: VAC source with optional power adapter (PSAC08 (US) or PSAC09 (European) providing 12 VDC, 1A). HF-20 Installation: Model AC150W Power Supply / System Monitor (110/250 VAC, ±10%; 47-63 Hz (auto-selecting)). Environment: 0° to +50°C (32° to +122°F) operating temperature; up to 95% relative humidity (non-condensing); up to 10,000 feet altitude; storage temperature -40° to +70° C.
*Note: Multimode tests were performed on 62.5/125 M fiber optic cable @ 2Kbps.Single Mode tests were performed on 10/125 M fiber optic cable @ 2Kbps.SECTION 2INSTALLATION
2.1 GENERAL
This section contains detailed information on the installation and initial checkout of the Model F220x / F224x Isolators. Paragraph 2.2 contains general information on site selection and rack mounting. Paragraph 2.3 contains instructions for connecting a Model F220x / F224x Isolator to your system and selecting the different options. Paragraph 2.4 contains initial checkout procedures. 2.2 SITE SELECTION AND MOUNTINGModel F220x / F224x Isolators are designed to connect directly to the serial port (DB25 Connector) with a customer-supplied cable. Installation options include standalone enclosure Models HF-1 (single card) or HF-2 (dual card) and rack mountable chassis Models HF-2SS (2-slot) and HF-20 (20-slot). 2.2.1 Signal InterfaceTable 4 lists the signal interface pinout for the F220x Transmitters and Table 5 lists the signal interface pinout for the F224x Receivers. Both Isolators have a DB25 Female connector.
2.2.2 User Selected OptionsSeveral jumpers are provided on the Model F220x / F224x Isolators. Both may be set for unbalanced or balanced signals in/out. They may be set differently, so that the Isolator pair becomes an interface converter. The Model F224x Receivers additionally can be set for a 0 or 180 phase shift of the output data. Another jumper (JP2) on the Model F220x Transmitters selects between the front-panel push-button and Pin 6 of the DB25 interface as the activation of the contact closure function. Tables 2 and 3 provide lists of all options available via jumper settings. 2.3 POWER REQUIREMENTSThe Model F220x Isolators operate from an AC power source and a power adapter or a DC power source with a DC voltage of +12 VDC, 1A. The power adapters used when installed in a Model HF-1 or HF-2 enclosure, or in a Model HF-2SS chassis are Model PSAC08 (US) or Model PSAC09 (European) providing 12VDC, 1A. Connect the power adapter to the Isolator before inserting its plug into an AC power source. No special tools are required. DC power may be used instead of an AC power adapter, if available. This requires a 2.5mm socket with positive on the center and common on the concentric. When installed in a Model HF-20 chassis, a Model AC150W Power Supply / System Monitor supplies power to all FOM II series circuit cards installed in the HF-20 chassis. Note that a Model AC150W utilizes two slots in a Model HF-20 chassis. For power redundancy, two Model AC150W units are recommended. 2.4 INITIAL CHECKOUT PROCEDURE
Model F220x Isolators contain no power on/off switch. Once you install and apply power to the unit, it is fully operational. The power indicator should remain on as long as power is supplied to the unit. To ensure proper operation, before beginning system operation verify: 1. Power plugs are seated fully into the Isolator or if in a Model HF-20 chassis, the Isolator is seated firmly in the chassis. 2. Fiber optic cables are connected from transmit channel 1 or 2 to receive channel 1 or 2, respectively, from unit one to unit two. 3. Alarm LED goes out when a signal is applied to the Model F220x Isolator DB25 interface. 4. Alarm LED on the Model F224x goes out when a signal is applied to the Model F220x Isolator DB25 interface and fiber is connected between the two units. If a malfunction is detected during the initial checkout procedure, refer to Chapter 5 for information on isolating the malfunction in the unit.
*¹ These jumpers are on the daughterboards within the optic modules and are factory set fornon-inverted signals (0 phase shift).TABLE 2. JUMPER SETTINGS, MODEL F220x TRANSMITTER
TABLE 3. JUMPER SETTINGS, MODEL F224x RECEIVER
Table 4 Table 5* The contact closure function is activated via Pin 6 of the Model F220x Transmitter or by the front-panel RESYNC push-button. When Pin 6 is grounded, the Resync signal is transmitted (active). If Pin 6 is +5V or floating, Resync is OFF and no signal is transmitted by the Model F220x Transmitter. Jumper JP2 on the circuit board allows the user to choose between Pin 6 and the front-panel push-button. With JP2 set in the 1-2 position, the Resync push-button is ON. With JP2 set in the 2-3 position, the Resync push-button is OFF and contact closure is via Pin 6 of the DB25.** The contact closure control output comes via Pins 3, 4 and 5 of the Model F224x Receiver DB25 interface. The contact closure device may be wired to Pins 3 & 4 ("normally OPEN") or Pins 4 & 5 ("normally CLOSED").DB25F CONNECTOR Pin AllocationsSECTION 3OPERATION3.1 INTRODUCTIONThis chapter contains a description of the operating controls and indicators associated with the Model F220x / F224x Isolators. Since the isolators are designed for continuous and uninterrupted operation, there are no operating requirements.
3.2 STATUS INDICATORS/AUDIBLE ALARMThere are four LED status indicators on the Model F220x Transmitter: DC power ON (PWR), Alarm (loss of signal) (ALM), Transmit (TX), and Resync. There are also four status indicators on the Model F224x Receiver: DC power ON (PWR), Alarm (loss of signal) (ALM), Receive Ch. 1 (RXC1), and Receive Ch. 2 (RXC2). No audible alarm is available.
3.3 OPERATING CONTROLSThe only operating controls associated with the Isolators are the front-panel push-button on the F220x Transmitters and those jumpers on the circuit card used to select between unbalanced and balanced, phase-shifted and non-phase-shifted signals. Settings of the jumpers, as described in Tables 2 and 3 of the previous section, permit the input and output of signal levels meeting EIA RS-232, EIA RS-422, EIA RS-423, MIL-STD-188-114 balanced or unbalanced, TTL, and/or NRZ standards. The selection of jumpers is normally done during installation, and therefore the standard transmission and reception of data across the fiber optic path require no operator intervention. The front-panel push-button on the Model F220x Transmitter provides initiation of the contact closure, or resynchronization provided jumper JP2 is set to position 1-2. Otherwise the contact closure may be activated remotely using Pin 6 of the Model F220x Transmitter DB25 interface. After installation, further changes are typically not required unless the system requirements change. SECTION 4THEORY OF OPERATION
4.1 INTRODUCTIONModel F220x / F224x Isolators are capable of transmitting and receiving one simplex signal at a data rate of 250bps to 10Mbps, plus one contact closure (resynchronization) signal. Balanced or unbalanced data signals may be isolated and converted from one to the other, with full transparency for the links. 4.2 DUAL CHANNEL TRANSMITTER F220xThe Model F220x Transmitter provides two dedicated simplex channels. The first channel handles a digital clock or data signal. The user has the option of inputting a balanced signal as specified in the EIA-RS-422 or MIL-STD-188-114 balanced digital interface specification, or an unbalanced signal as per EIA-RS-423, MIL-STD-188-114, RS-232 or MIL-STD-188C specifications. The circuit board contains separate device drivers, user selectable by jumpers as described in Section 2, for both signal types. The second simplex channel transmits a contact closure control signal, input from the front-panel push-button or from the DB25 interface. Both unbalanced and balanced data plus contact closure inputs are converted to TTL (+5V or Ground) prior to input to the optic modules. The optic modules convert the TTL digital data stream to light and provide the connection to the fiber optic cable. 4.3 DUAL CHANNEL RECEIVER F224xThe Model F224x Receiver provides the inverse process of the F220x Transmitter. Light signals are received by two optic modules. Isolation is maintained between the two channels as well as between electrical interfaces by the two independent optical paths. Like the Transmitter circuit, the Receiver circuit contains user-selectable options for a balanced or unbalanced data signal on Channel 1 of the Receiver. Setting the F224x Receiver jumpers the same as the F220x Transmitter enables a "transparent" path from the input to the transmitter to the output of the receiver. However, signal translation from balanced to unbalanced or vice versa, as well as a phase inversion (EIA-to-MIL-STD), is also possible. The second channel of the F224x Receiver provides the contact closure signal. As described in the footnote to Table 5, the contact closure Normally-OPEN / Normally- CLOSED output connections are provided. 4.4 POWER SUPPLY AND ALARM CIRCUITRYThe power supply used for the F220x and F224x Isolators utilizes a regulated +12VDC from a Model HF-20 chassis or an unregulated +12VDC from Model PSAC08 (US) or PSAC09 (European) power adapter. The source power is directed through a slo-blo fuse, filtered and re-regulated to furnish +5V and - 5V supplies throughout the circuit board. If either the +5V or -5V supplies fail, or if the +12V supply is not working, an alarm condition occurs. Standard FOM II alarm circuitry monitors both channels in addition to the power supplies. LED indicators are triggered on the circuit board and on the Model AC150W power supply by the alarm circuitry. SECTION 5MAINTENANCE AND TROUBLESHOOTING
5.1 INTRODUCTIONThis chapter contains general information designed to isolate a malfunction in the Model F220x / F224x Isolator to a replaceable unit. These units are not equipped with redundancy. Therefore, a failure in one of these units would interrupt service. 5.2 FAULT ISOLATIONSteps in Table 6 should be taken to troubleshoot a non-operating modem. Contact VERSITRON Customer Service for diagnostic assistance or to arrange for repair.
TABLE 6. NON-OPERATIONAL INDICATORS
If you are still experiencing problems, please contact VERSITRON customer service for assistance at 302-894-0699 or 800-537-2296. Return To Versitron.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||