M8000T Series RS-232 / MIL-STD-188C (Unbalanced) Fiber Optic MicroModem Technical Manual
See Technical Data Sheet Revision E VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 PROPRIETARY DATA All data in this manual is proprietary and may not be disclosed, used or duplicated, for procurement or manufacturing purposes, without prior written permission by VERSITRON, Inc.
All VERSITRON products purchased after January 2001 carry a limited lifetime warranty against defects in material and workmanship. Purchases made prior to January 2001 are warranted for a period of one year from date of delivery. VERSITRON reserves the right to repair or, at our option, replace parts which during normal usage prove to be defective during the warranty period provide that: 1. You call VERSITRON at 302-894-0699 or 800-537-2296 and obtain a Return Maintenance Authorization (RMA) Number. Please reference your RMA number on the outside of the box in which the item is shipped. 2. Shipping charges are pre-paid. No other warranty is expressed or implied and we are not liable for consequential damages. For repairs outside of the warranty period, the same procedure must be followed. TABLE OF CONTENTS SECTION 1 DESCRIPTION OF EQUIPMENT 1.1 INTRODUCTION 1.2 DESCRIPTION OF EQUIPMENT 1.2.1 Functional Characteristics 1.2.2 Physical Characteristics FIGURE 1. OVERALL VIEW, M8000T MICROMODEM FIGURE 2. INTERFACE EXTENDER CONFIGURATION FIGURE 3. MODEM LINK CONFIGURATION 1.3 SPECIFICATIONS SECTION 2: INSTALLATION 2.1 GENERAL 2.2 SITE SELECTION AND MOUNTING FIGURE 2. OVERALL VIEW, MRR-16 CHASSIS 2.2.1 Signal Interface 2.2.2 User Selected Options 2.3 POWER REQUIREMENTS FIGURE 5. SWITCH SETTINGS 2.3.1 Installation with AC Power 2.3.2 Installation with DC Power 2.4 INITIAL CHECKOUT PROCEDURE SECTION 3: OPERATION 3.1 INTRODUCTION 3.2 STATUS INDICATORS/AUDIBLE ALARM 3.3 Operating Controls SECTION 4: THEORY OF OPERATION 4.1 INTRODUCTION SECTION 5: MAINTENANCE AND TROUBLESHOOTING 5.1 INTRODUCTION 5.2 FAULT ISOLATION SECTION 1 DESCRIPTION OF EQUIPMENT 1.1 INTRODUCTION This manual provides general and detailed information on the installation and operation of the M8000T Series MicroModems. Section 1 contains a general description of the equipment. Section 2 contains installation instructions. Section 3 contains operating instructions. Section 4 provides the theory of operation. Section 5 contains maintenance and troubleshooting information.
1.2 DESCRIPTION OF EQUIPMENT 1.2.1 Functional Characteristics The M8000T Series Fiber Optic MicroModems provide copper-to-fiber conversion for data transmission over fiber optic cable as interface extenders or as modem links for synchronous or asynchronous data. M8213T and M8223T models are equipped with multimode 850nm LED optics and can transmit over a pair of multimode fiber cables for up to 2 Km (6,600 ft). M8214T and M8224T models are equipped with multimode 1300nm LED optics and can transmit over a pair of multimode fiber cables for up to 8 Km (26,400 ft). M8215T and M8225T models are equipped with single mode 1300nm LED optics and can transmit over a pair of single mode fiber cables for up to 15 Km (49,500 ft). The link is fully transparent in both directions and is data agile for any data rate from 1 Bps to 100 Kbps with terminal timing or from 1 Bps to 64 Kbps with source timing. Interface control signals associated with RS-232 and MIL-STD-188C Unbalanced standards are fully supported. This is accomplished by multiplexing the control signals along with the clock and data signals and transmitting the combined signal to the remote unit. At the remote end the combined signal is demultiplexed and applied to the interface. 1.2.2 Physical Characteristics The M8000T Series Fiber Optic MicroModems measure 2.5 x 1.0 x 4.5in (6.35 x 2.54 x 11.43cm) (HxWxL). Housed in extruded aluminum, these modems are self-contained and may be mounted directly to electrical interface connectors. M821XT is a DCE unit with a female DB25 for connecting to a terminal electrical interface. The M822XT is a DTE unit with a male DB25 for connecting to a modem electrical interface. ST optical connectors are standard for all models with the transmitter optic located closest to the power connector.
FIGURE 1. OVERALL VIEW, M8000T MICROMODEM MicroModems require VDC power for operation, with a one-pin connector for electrical input. VDC power (+5 to +15 VDC) may be applied to pin 9 of the DB25 interface if host power is available. An external power adapter is available for converting VAC to VDC if host power or chassis power is not used. Reference Section 2.3 for more information. A 19" standard rack mount chassis (Model MRR-16) is available for rack mounting up to 16 MicroModems (Figure 4). The Model MRR-16 chassis measures 19 x 3.5 x 11.2 in (48.3 x 8.9 x 28.4 cm) and receives power from a power supply (Model M0004) providing VDC power from a VAC power source. Two Model M0004 power supplies are recommended for power redundancy. The M0004 power supply measures 1.3 x 2.5 x 5.1 in (3.33 x 6.35 x 13.02 cm). The M0004 power supplies provide VDC power to the MRR-16 chassis power bus bar. From the power bus bar, VDC is provided to each modem by a 6" power cable (Model M0001). Please note that each MicroModem requires a Model M0001 power cable.
FIGURE 2. INTERFACE EXTENDER CONFIGURATION
FIGURE 3. MODEM LINK CONFIGURATION 1.3 SPECIFICATIONS Data Signal: Signal level and format conform to EIA RS-232 and MIL-STD-188C Unbalanced standards. Data Rate: Source Timing - continuously variable from 1 Bps to 64 Kbps for synchronous or asynchronous signals. Terminal Timing: continuously variable from 1 Bps to 100 Kbps for synchronous or asynchronous signals. Operating Mode/Range: Full duplex or simplex operation over a fiber optic cable pair with maximum range of 2 Km (6,600 ft) for 850nm multimode optics, 8 Km (26,400 ft) for 1300nm multimode optics, and 15 Km (49,500 ft) for 1300nm single mode optics. Optical Specifications:
*Note Multimode tests were performed on 62.5/125 µM fiber optic cable. Single Mode tests were performed on 9/125 µM fiber optic cable.
Electrical Connector: DCE - DB25 female for terminal interface connections. DTE: DB25 male for modem interface connections. Bit Error Rate: Better than 10-9 . Sampling Rate: 300 KHz (clock and data), 18.75 KHz (control lines). When asynchronous data is applied to control lines, there is approximately 5% jitter at a data rate of 1 Kbps. Dimensions: 2.5 x 1.0 x 4.5 in (6.35 x 2.54 x 11.43 cm) (HxWxL) Weight: 6 oz (0.17 kg) Power Requirements: 115/230 VAC, 1.4 Watts, with power adapter providing 12 VDC, 1 A (Model PSAC08, US; Model PSAC09, European). If using host power, +5 to +15 VDC may be provided on pin 9 of the DB25 connector. Environment: 0° to +50°C (32° to +122°F) operating temperature; up to 95% relative humidity (non-condensing); up to 10,000ft altitude; storage temperature -40° to +70°C.
2.1 GENERAL This section contains information on installation and checkout of the M8000T Series Fiber Optic MicroModems. Paragraph 2.2 contains general information on site selection and rack mounting. Paragraph 2.3 contains instructions for making connections to your system and selecting options. Paragraph 2.4 contains initial checkout procedures. 2.2 SITE SELECTION AND MOUNTING The M8000T Series Fiber Optic MicroModems connect to the electrical interface with two hand-tightened jackscrews. When mounting to a PC, facsimile equipment or STU III telephone, securely position the modem allowing space for the power adapter, if used. Up to 16 MicroModems may be installed in a MRR-16 rack mount chassis (Figure 4). The MRR-16 chassis measures 19.0 x 3.5 x 11.2 in (48.3 x 8.9 x 28.4 cm) (HxWxL). Model M0004 power supply provides VDC power to the chassis from a VAC power source. Two Model M0004 power supplies may be plugged into the MRR-16 chassis for power redundancy. When MicroModems are installed into the Model MRR-16 chassis each MicroModem requires a Model M0001 6" power jumper cable.
FIGURE 2. OVERALL VIEW, MRR-16 CHASSIS
2.2.1 Signal Interface DCE modems have a DB25 female connector for the terminal interface connection. DTE modems have a DB25 male connector for the modem interface connection. 2.2.2 User Selected Options An internal switch, SW1, is provided to select EIA or MIL operation (Figure 5). Default settings for SW1 Positions 1, 2, 3, 4 and 6 are OFF; Positions 5, 7 and 8 are ON. With switch position 7 in the ON position, the modem is set for EIA operation. With switch position 7 in the OFF position, MIL operation is set. By selecting EIA on one end of the link and MIL on the other, interface conversion occurs. The rest of the switches on the circuit board are for diagnostic purposes only and should not be moved by the user. 2.3 POWER REQUIREMENTS The M8000T Series Fiber Optic MicroModems operate either from a VAC to VDC power adapter or a VDC power source with a DC voltage of +5 to +15. Using pin 9 of the DB25 connector, host power may be used to supply modem power. Power adapters used are Model PSAC08 (US) for 115 VAC input and Model PSAC09 (VDE) for 230 VAC input.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||